Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
J Appl Clin Med Phys ; 22(8): 219-229, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1293131

ABSTRACT

BACKGROUND: To conserve personal protective equipment (PPE) and reduce exposure to potentially infected COVID-19 patients, several Californian facilities independently implemented a method of acquiring portable chest radiographs through glass barriers that was originally developed by the University of Washington. METHODS: This work quantifies the transmission of radiation through a glass barrier using six radiographic systems at five facilities. Patient entrance air kerma (EAK) and effective dose were estimated both with and without the glass barrier. Beam penetrability and resulting exposure index (EI) and deviation index (DI) were measured and used to adjust the tube current-time product (mAs) for glass barriers. Because of beam hardening, the contrast-to-noise ratio (CNR) was measured with image quality phantoms to ensure diagnostic integrity. Finally, scatter surveys were performed to assess staff radiation exposure both inside and outside the exam room. RESULTS: The glass barriers attenuated a mean of 61% of the normal X-ray beams. When the mAs was increased to match EI values, there was no discernible degradation of image quality as determined by the CNR. This was corroborated with subjective assessments of image quality by chest radiologists. The glass-hardened beams acted as a filter for low energy X-rays, and some facilities observed slight changes in patient effective doses. There was scattering from both the phantoms and the glass barriers within the room. CONCLUSIONS: Glass barriers require an approximate 2.5 times increase in beam intensity, with all other technique factors held constant. Further refinements are necessary for increased source-to-image distance and beam quality in order to adequately match EI values. This does not result in a significant increase in the radiation dose delivered to the patient. The use of lead aprons, mobile shields, and increased distance from scattering sources should be employed where practicable in order to keep staff radiation doses as low as reasonably achievable.


Subject(s)
COVID-19 , Consensus , Humans , Phantoms, Imaging , Radiation Dosage , Radiography, Thoracic , SARS-CoV-2
2.
J Am Coll Radiol ; 17(7): 839-844, 2020 Jul.
Article in English | MEDLINE | ID: covidwho-357037

ABSTRACT

The ACR recognizes that radiology practices are grappling with when and how to safely resume routine radiology care during the coronavirus disease 2019 (COVID-19) pandemic. Although it is unclear how long the pandemic will last, it may persist for many months. Throughout this time, it will be important to perform safe, comprehensive, and effective care for patients with and patients without COVID-19, recognizing that asymptomatic transmission is common with this disease. Local idiosyncrasies prevent a single prescriptive strategy. However, general considerations can be applied to most practice environments. A comprehensive strategy will include consideration of local COVID-19 statistics; availability of personal protective equipment; local, state, and federal government mandates; institutional regulatory guidance; local safety measures; health care worker availability; patient and health care worker risk factors; factors specific to the indication(s) for radiology care; and examination or procedure acuity. An accurate risk-benefit analysis of postponing versus performing a given routine radiology examination or procedure often is not possible because of many unknown and complex factors. However, this is the overriding principle: If the risk of illness or death to a health care worker or patient from health care-acquired COVID-19 is greater than the risk of illness or death from delaying radiology care, the care should be delayed; however, if the opposite is true, the radiology care should proceed in a timely fashion.


Subject(s)
Coronavirus Infections/prevention & control , Infection Control/standards , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Practice Management, Medical/standards , Radiology , Universal Precautions , Betacoronavirus , COVID-19 , Coronavirus Infections/transmission , Cross Infection/prevention & control , Humans , Occupational Exposure/prevention & control , Personal Protective Equipment , Pneumonia, Viral/transmission , Risk Assessment , SARS-CoV-2 , United States
SELECTION OF CITATIONS
SEARCH DETAIL